Model 17-..,37-..,47-..,57-.., General Characteristics |
||||||
|---|---|---|---|---|---|---|
|
All currently available models |
(Electronic) Modules:
Optional:
Terminals:
Approvals:
|
|||||
| MODEL | RATING | CONTACT GAP | APPROVALS | REMARK |
FEATURES
APPLICATIONS |
|
| 125V AC | 230V AC | |||||
| 17-.. |
VSC 4A |
VSC 3A |
2 mm |
UL/CSA |
Internal heatsink |
Heavy duty contacts for long life and high stall currents |
|
VSC 6A |
VSC 4A |
Wrap-around heatsink |
||||
|
VSC 8A |
VSC 4A |
External (remote) power element |
||||
|
O/O 8A |
O/O 4A |
- |
||||
| VSC 12A | - | CSA us |
External (remote) power element |
|||
| O/O 12A | - |
- |
||||
| 37-.. |
VSC 4A |
- | 2 mm | UL/CSA |
Internal heatsink |
Light duty version of model 17-.. |
| 47-.. |
VSC 4A |
VSC 3A | 3 mm |
UL/CSA (IEC) |
- |
Alternative
to model 17-.. with 3 mm contact gap. When properly wired this allows IEC approval of the tool |
|
VSC 6A |
VSC 4A |
- |
||||
|
VSC 8A |
VSC 6A |
External (remote) power element |
||||
|
O/O 8A |
O/O 6A |
- |
||||
| VSC 12A | - | CSA us |
External (remote) power element |
|||
| O/O 12A | - |
- |
||||
| 57-.. | - | VSC 4A | 3 mm | IEC |
- |
With a terminal connected |
| - | VSC 6A | - | ||||
| - |
O/O 6A |
- |
||||
Model 27-..,67-..,77-.., General Characteristics(Overhang shape) |
||||||
|---|---|---|---|---|---|---|
|
All currently available models |
(Electronic) Modules:
Optional:
Terminals:
Approvals:
|
|||||
| MODEL | RATING | CONTACT GAP | APPROVALS | REMARK |
FEATURES
APPLICATIONS |
|
| 125V AC | 230V AC | |||||
| 27-.. |
VSC 4A |
VSC 3A |
2 mm |
UL/CSA |
Internal heatsink |
Heavy duty contacts for long life and high stall currents |
|
VSC 8A |
VSC 4A |
External (remote) power element |
||||
|
O/O 8A |
O/O 4A |
- |
||||
| VSC 12A | - | c CSA us |
External (remote) power element |
|||
| O/O 12A | - |
- |
||||
| 67-.. | - | VSC 4A | 3 mm | IEC |
- |
With a terminal connected |
| - | VSC 6A | - | ||||
| - |
O/O 6A |
- |
||||
| 77-.. |
VSC 4A |
VSC 3A | 3 mm |
UL/CSA (IEC) |
- |
Alternative
to model 27-.. with 3 mm contact gap. When properly wired this allows IEC approval of the tool |
|
VSC 8A |
VSC 6A |
External (remote) power element |
||||
|
O/O 8A |
O/O 6A |
- |
||||
| VSC 12A | - | c CSA us |
External (remote) power element |
|||
| O/O 12A | - |
- |
||||
General remark:
The CAPAX AC Switch Application Guidelines Manual supplies additional technical information for making the optimized selection.
However it is recommended to have the chosen combination approved by CAPAX Engineering Department.
Maximum power is for non-adjustable versions. Adjustable versions may reduce the power.
Amp rating data defined by approval boards. Application has to match the capabilities of the electronics.
The application may very over a wide range, depending on motor and tool characteristics.